The Thermo Scientific TRACE 1110 GC is a new multi-channel, high performance, flexible and robust gas chromatograph offering up to four injectors and four detectors running simultaneously on the same GC. This capability allows users to efficiently switch between different applications on the same GC. With these offerings, Trace 1110 GC is capable of easily handling routine and challenging applications in the most cost effective way.

Superior Performance with Multiple Configurations

The Thermo Scientific TRACE 1110 GC comes with an array of injection and detection options, smart accessories, and auxiliary devices. It has a capacity to mount up to four injection ports and four detectors. TRACE 1110 GC with the largest oven size in the market, can accommodate maximum number of capillary columns, leading to increased productivity and performance. TRACE 1110 GC provides the highest reproducibility in terms of retention time and peak area. TRACE 1110 GC is a robust GC in line with global standards.

High Quality Data

The TRACE 1110 GC offers options for highly integrated Electronic Pressure Control (EPC) or easier and simpler manual pneumatic control of gases. The high performance EPC gives excellent retention time reproducibility. It includes gas saver facility to reduce consumption of carrier gas and running costs.

Customised Solutions

The wide range of accessories makes TRACE 1110 GC a highly flexible and solution tuning gas chromatograph. It provides dedicated and customised solutions for turnkey analyzers. The range includes analyzers for petrochemical, environmental, food safety, chemical and pharmaceutical applications.

Performance Specifications

  • Typical Retention Time Repeatability: 0.008 min
  • Typical Peak Area Repeatability: <2% RSD

Oven Specifications

  • Column Oven (H × W × D): 30.9 x 29.0 x 26.0 cm; 22.6 L
  • Operating Temperature Range: ambient +5 °C to 500 °C
  • Cryogenic Option Minimum Temperature: -99 °C with liquid Nitrogen
  • Temperature Set Point Resolution: 1 °C
  • Number of Ramps/Plateaus: 7/8
  • Maximum Heating Rate: 50 °C/min
  • Oven Cool-Down (22 °C ambient): 400 °C to 50 °C in < 6 min

EPC (Electronic Pressure Control)

  • Up to 10 channels of integrated electronic gas control
  • Pressure Set Points Minimum Increments: 0.01 psi in all ranges

Carrier Gas Control Capillary and PTV Injectors

  • Pressure Range: 0–1000 kPa (0–145 psi)
  • Modes: Constant Pressure, Constant Flow and Programmed Pressure

Injectors

  • Maximum Number of Injectors: 4

Packed Column

  • Suitable for 1/4", 1/8", 1/16" packed columns and wide bore capillary columns (0.53 mm i.d.) with adaptor
  • Temperature Range: 50 C - 450 C, with manual pneumatics or MFC

Split/Splitless

  • Suitable for all (0.1 mm to 0.53 mm i.d.) capillary columns
  • Temperature Range: 50 C - 450 C with manual pneumatics or Electronic Pressure Control (EPC)
  • Constant pressure & constant flow modes
  • Pressure programming with three ramps and four plateaus
  • Gas saver mode: Standard
  • Carrier Flow Setting: 0.1 ml/min to 100 ml/min
  • Split Flow Setting: 1 ml/min to 400 ml/min
  • Modes: Split and Splitless
  • Purge Flow Setting: 0 to 50 ml/min
  • Split Ratio: Up to 9999:1

PTV (Programmed Temperature Vaporizer)

  • Suitable for all (0.1 mm to 0.53 mm i.d.) capillary columns
  • Temperature Range: 50 C - 450 C with Electronic Pressure Control (EPC)
  • Constant pressure & constant flow modes
  • Pressure programming with three ramps and four plateaus
  • Gas saver mode: Standard
  • Modes: Split, Splitless and Solvent Split
  • Carrier Flow Setting: 0.1 ml/min to 100 ml/min
  • Split Flow Setting: 1 ml/min to 400 ml/min
  • Purge Flow Setting: 0 to 50 ml/min
  • Temperature Programming Rate: 1 C/min to 0 600 C/min

Detectors

  • Maximum Number of Detectors: 4
  • Detectors Available: Flame Ionization Detector, Thermal Conductivity Detector, Electron apture Detector, Flame Photometric Detector and Nitrogen Phosphorus Detector
  • Acquisition Rate: Up to 50 Hz
  • Pneumatics: Manual pneumatics or EPC for gas flow control

Flame Ionization Detector

    • Compatible with 1/4", 1/8", 1/16” and capillary columns
    • Flameout detection
    • MDL: <3 pg C for C9 hydrocarbon
    • Linear Dynamic Range: >10
    • Maximum Temperature: 450 C
    • Flow Setting: - Air: 0-400 ml/min - H2: 0-150 ml/min - Makeup gas 0-150 ml/min

Thermal Conductivity Detector

  • Compatible with 1/4", 1/8", 1/16" and capillary columns
  • MDL: <800 pg C12/ml He
  • Sensitivity: 10 μV /ppm for Nonane
  • Linear Dynamic Range: >10
  • Maximum Temperature: 400 C

Electron Capture Detector

  • Radioactive Source: 370 MBq equal to 63 10 mCi, Ni
  • Cell Volume: <350 μl
  • MDL: <1×10 g/s Lindane
  • Sensitivity: 0.1 pg/s Lindane
  • Linear Dynamic Range: >10
  • Maximum Temperature: 400 C
  • Makeup Gas: Nitrogen or 5% Methane in Argon
  • Makeup Gas flow: 0-50 ml/min

Nitrogen Phosphorus Detector

  • NPD available with ceramic beads and compatible with element-specific sources
  • MDL: < 0.1pg N/sec for Azobenzene < 0.5pg P/sec for Methyl-Parathion
  • Selectivity: gN/gC = 20,000; gP/gC = 40,000
  • Linear Dynamic Range: >10
  • Current Setting: 1 to 3.5 A
  • Maximum Temperature: 450 C
  • Flow Setting: - Air : 0-100 ml/min - H : 0-50 ml/min 2 - Makeup Gas: 0-50 ml/min

General Specifications

  • Heated Zones: Up to 11
  • Time Events: Up to 8
  • Operating Voltage: 230V, 50 Hz
  • Dimensions: (H × W × D): 57 × 61 × 64 cm
  • Weight: 65 kg approximate

Other Detectors

  • PID/ PDHID/ PFPD/ FPD

Accessories

  • Liquid Autosampler
  • Headspace Sampler
  • Heated Valve Oven for Turnkey Analyzers
  • Gas Sampling Valve
  • Liquid Sampling Valve
  • Pyrolyzer
  • Purge and Trap
  • Thermal Desorber
  • Optional built-in mini UPS

Certifications

  • CE certification